From Authentication Authorization and Accounting Service Security Requirements Guide
Part of SRG-APP-000374-AAA-000034
Associated with: CCI-001890
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Verify the AAA Service is configured to use or map to UTC to record time stamps for audit records. The audit records must either show UTC time or an offset to UTC time for each entry. If the AAA Service is not configured to use or map to UTC to record time stamps for audit records, this is a finding.
Configure the AAA Service to use or map to UTC to record time stamps for audit records.