The storage system must allocate audit record storage capacity to store at least one weeks worth of audit records, when audit records are not immediately sent to a central audit record storage facility.

From HPE 3PAR StoreServ 3.2.x Security Technical Implementation Guide

Part of SRG-OS-000341-GPOS-00132

Associated with: CCI-001849

SV-85135r1_rule The storage system must allocate audit record storage capacity to store at least one weeks worth of audit records, when audit records are not immediately sent to a central audit record storage facility.

Vulnerability discussion

To verify operating systems have a sufficient storage capacity in which to write the audit logs, operating systems need to be able to allocate audit record storage capacity.The task of allocating audit record storage capacity is usually performed during initial installation of the operating system.

Check content

Verify the logging capacity is set to the maximum value of "4", with the following command: cli% showsys -param If the resulting list of configured parameters and values, does not contain "EventLogSize : 4M", this is a finding.

Fix text

Configure the audit logging capacity for the maximum storage value by entering the command: cli% setsys EventLogSize 4M