From Juniper SRX SG NDM Security Technical Implementation Guide
Part of SRG-APP-000435-NDM-000315
Associated with: CCI-002385
Service redundancy, may reduce the susceptibility to some DoS attacks.
If service redundancy is not required by the organization's policy, this is not a finding. Verify the configuration is working properly: [edit] show chassis cluster interfaces command. If service redundancy is not configured, this is a finding.
Interfaces can be monitored by a redundancy group for automatic failover to another node. Assign a weight to the interface to be monitored. This configuration is an extremely complex configuration. Consult the vendor documentation. Set the chassis cluster node ID and cluster ID. Configure the chassis cluster management interface. Configure the chassis cluster fabric. Configure the chassis cluster redundancy group Specify the interface to be monitored by a redundancy group. Specify the interface to be monitored by a redundancy group. Example: [edit] set chassis cluster redundancy-group 1 interface-monitor ge-6/0/2 weight 255