The Juniper SRX Services Gateway must record time stamps for log records using Coordinated Universal Time (UTC).

From Juniper SRX SG NDM Security Technical Implementation Guide

Part of SRG-APP-000374-NDM-000299

Associated with: CCI-001890

SV-80973r1_rule The Juniper SRX Services Gateway must record time stamps for log records using Coordinated Universal Time (UTC).

Vulnerability discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis. UTC is normally used in DoD; however, Greenwich Mean Time (GMT) may be used if needed for mission requirements.

Check content

Verify the time zone is set to UTC. [edit] show system time-zone If the time zone is not set to UTC, this is a finding.

Fix text

The following command sets the time zone to UTC. [edit] set system time-zone UTC