From Juniper SRX SG NDM Security Technical Implementation Guide
Part of SRG-APP-000360-NDM-000295
Associated with: CCI-001858
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process logs as required. Without an immediate alert for critical system issues, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.
Verify the system Syslog has been configured to display an alert on the console for the emergency and critical levels of the daemon facility. [edit] show system syslog If the system is not configured to generate a system alert message when a component failure is detected, this is a finding.
The following commands configure syslog to immediately display any emergency level or daemon alert events to the management console. The message will display on any currently logged on administrator's console. This is an example method. Alerts must be sent immediately to the designated individuals (e.g., via Syslog configuration, SNMP trap, manned console message, or other events monitoring system). [edit] set system syslog user * any emergency set system syslog user * daemon alert set system syslog user * daemon critical
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer