From Cisco IOS XE Release 3 NDM Security Technical Implementation Guide
Part of SRG-APP-000375-NDM-000300
Associated with: CCI-001889
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
Verify that the time stamps for audit records have a granularity of one second. The configuration should look similar to the example below: service timestamps debug datetime msec service timestamps log datetime year If the time stamps have a granularity larger than one second, this is a finding.
Configure the Cisco IOS XE router to have a granularity of one second for audit log time stamps. The configuration should look like the example below: service timestamps debug datetime msec service timestamps log datetime year