From Cisco IOS XE Release 3 NDM Security Technical Implementation Guide
Part of SRG-APP-000374-NDM-000299
Associated with: CCI-001890
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Verify that the Cisco IOS XE router time stamps for audit logs can be mapped to UTC or GMT by using the show logging command. The configuration should look similar to the following example: clock timezone MST -7 0 service timestamps datetime localtime If the time stamps cannot be map to UTC or GMT, this is a finding.
Configure the timezone for the local time, then map the time stamps back to UCT or GMT. The configuration should look similar to the example below: clock timezone MST -7 0 service timestamps datetime localtime