From Multifunction Device and Network Printers STIG
Part of MFD/Printer Firewall/Router Rule Perimeter
Associated with IA controls: DCBP-1
Access to the MFD or printer from outside the enclave network could lead to a denial of service caused by a large number of large print files being sent to the device. Ability for the MFD or printer to access addresses outside the enclave network could lead to a compromise of sensitive data caused by forwarding a print file to a location outside of the enclave network. This is good defence in depth practice.
The reviewer will interview the SA to verify that there is a firewall or router rule to block all ingress and egress traffic from the enclave perimeter to the MFD or printer.
Ensure that there is a firewall or router rule to block all ingress and egress traffic from the enclave perimeter to the MFD or printer.