From Video Services Policy STIG
Part of RTS-VTC 7080 [IP]
Associated with IA controls: ECSC-1, DCSS-2
A factory reset is the software restore of an electronic device to its original system state by erasing all of the information stored on the device to restore the device to its original factory or unconfigured settings. This erases all of the data, settings, and applications that were previously on the device. Factory reset may be used as part of the sanitization process.
Verify that the VTC system has an automated configuration management system configured to sanitize and reconfigure the CODEC when transitioning between networks. If it does, review documentation to determine that this capability is being implemented. If these conditions are met, this is not a finding. If the unit is not implementing an automated process, review documentation to determine whether a manual procedure is specified and implemented when transitioning between networks; this will result in a CAT III finding if these conditions are met and a CAT II finding if they are not. If an automatic capability exists but is not being implemented or an automated configuration management system is not being used, this is a CAT II finding unless a manual procedure is specified and is being implemented, then this is a CAT III finding. If the unit is not being sanitized when transitioning between networks, this is a CAT II finding.
Obtain a VTC system that has an automated sanitization capability. Implement and document a procedure that utilizes this capability to sanitize the CODEC when transitioning between networks. As a last resort, implement and document a manual sanitization / reconfiguration procedure to perform this function.
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer