From Riverbed SteelHead CX v8 NDM Security Technical Implementation Guide
Part of SRG-APP-000374-NDM-000299
Associated with: CCI-001890
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Verify that RiOS is configured select UTC. Navigate to the device Management Console Navigate to Configure >> System Settings >> Date and Time Verify that "UTC" is selected If no NTP Servers are visible after the command "show ntp all" or on "Requested Servers", this is a finding.
Configure RiOS enable UTC. Navigate to the device Management Console Navigate to Configure >> System Settings >> Date and Time Select "UTC" for the Time Zone Click "Apply" Navigate to the top of the web page and click "Save" to save these settings permanently