From Riverbed SteelHead CX v8 NDM Security Technical Implementation Guide
Part of SRG-APP-000360-NDM-000295
Associated with: CCI-001858
It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.
Verify that RiOS is configured to generate an immediate real-time alert for all audit failure events requiring real-time alerts. Navigate to the device Management Console Navigate to Configure >> System Settings >> Email Verify that an SMTP Server is defined Verify that an SMTP Port is defined Verify that "Report Events via Email" is checked and that at least one email address is defined Verify that "Report Failures via Email" is checked and that at least one email address is defined If no email accounts are defined, this is a finding.
Configure RiOS to generate an immediate real-time alert for all audit failure events requiring real-time alerts. Navigate to the device Management Console Navigate to Configure >> System Settings >> Email Enter an SMTP Server name Enter n SMTP Port number Check "Report Events via Email" and enter at least one email address Check "Report Failures via Email" and enter at least one email address
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer