From z/OS TSS STIG
Part of TSS0650
Associated with IA controls: DCCS-1, DCCS-2
Associated with: CCI-000174
The TIMER Control Option controls the interval at which data is written from TSS buffers to the audit tracking file.
a) Refer to the following report produced by the TSS Data Collectio - TSSCMDS.RPT(STATUS) Automated Analysis Refer to the following report produced by the TSS Data Collection: - PDI(TSS0650) b) If the TIMER Control Option value is set to TIMER(30), there is NO FINDING. c) If the TIMER Control Option value is NOT set to TIMER(30), this is a FINDING.
Evaluate the impact associated with implementation of the control option. Develop a plan of action to implement the control option setting to TIMER(30), and proceed with the change.