The DataPower Gateway must protect audit information from any type of unauthorized read access.

From IBM DataPower Network Device Management Security Technical Implementation Guide

Part of SRG-APP-000118-NDM-000235

Associated with: CCI-000162

SV-79565r1_rule The DataPower Gateway must protect audit information from any type of unauthorized read access.

Vulnerability discussion

Audit information includes all information (e.g., audit records, audit settings, and audit reports) needed to successfully audit information system activity.If audit data were to become compromised, then competent forensic analysis and discovery of the true source of potentially malicious system activity is difficult, if not impossible, to achieve. In addition, access to audit records provides information an attacker could use to his or her advantage.To ensure the veracity of audit data, the information system and/or the network device must protect audit information from any and all unauthorized read access.This requirement can be achieved through multiple methods which will depend upon system architecture and design. Commonly employed methods for protecting audit information include least privilege permissions as well as restricting the location and number of log file repositories.Additionally, network devices with user interfaces to audit records should not allow for the unfettered manipulation of or access to those records via the device interface. If the device provides access to the audit data, the device becomes accountable for ensuring audit information is protected from unauthorized access.

Check content

Login page >> Enter non admin user id and password, select Default for domain >> Click Login. If non admin user can log on, this is a finding.

Fix text

Privileged account user log on to default domain >> Administration >> Access >> User Account >> Select non privileged user account >> Click “…” button next to User Group field >> Enter */default/*?Access=NONE into field >> click add >> click Apply >> click Apply >> click Save Configuration

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.

You can obtain data about documents and items in other formats. Simply provide an HTTP header Accept: text/turtle or Accept: application/rdf+xml.

Powered by sagemincer