From Voice Video Services Policy STIG
Part of VVoIP 6150
The enhanced reliability and availability achieved by the implementation of redundancy and geographic diversity throughout the DISN Core along with the implementation of dual homed circuits via geographically diverse pathways and facilities is negated if both access circuits enter the enclave via the same facility containing a single Customer Edge Router (CER) connected to a single Session Border Controller (SBC). The reliability, redundancy, and robustness of the CER, SBC, and power source are subverted when the facility represents a single point of failure. For a small number of C2 users this may be less concerning but with more C2 users supported by the system, the greater the issue. Even less severe eventualities may limit the capability of the system to support reliable communications.
Review site documentation to confirm critical network equipment is redundant and in geographically diverse locations for a site supporting C2 users. Redundant sets of CERs, SBCs, and session controllers must be housed in geographically diverse facilities within the site such that if one of locations is lost or isolated from the network, communications service is maintained. Sites facilities with a Soft Switch should have a session controller implemented in a geographically diverse location. If critical network equipment does not have redundant equipment, this is a finding. If redundant critical network equipment is not in a geographically diverse location, this is a finding. If it is determined, following a cost versus benefit study and risk analysis, that redundant facilities containing dual sets of CERs, SBCs, and session controllers are not warranted for the given site, this requirement should be marked as a finding with a justification included in the POA&M stating the Authorizing Official (AO) is cognizant of and accepts the risk. NOTE: The VVoIP system may allow SIP and SRTP traffic encrypted and encapsulated on port 443 from Cloud Service Providers.
Implement and document critical network equipment as redundant and in geographically diverse locations for a site supporting C2 users. Critical network equipment includes CERs, SBCs, and session controllers (or Soft Switches in combination with session controllers). NOTE: The VVoIP system may allow SIP and SRTP traffic encrypted and encapsulated on port 443 from Cloud Service Providers.
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer