The Tanium cryptographic signing capabilities must be enabled on the Tanium Server.

From Tanium 6.5 Security Technical Implementation Guide

Part of SRG-APP-000131

Associated with: CCI-001749

SV-81465r2_rule The Tanium cryptographic signing capabilities must be enabled on the Tanium Server.

Vulnerability discussion

All of Tanium's signing capabilities should be enabled upon install. Tanium supports the cryptographic signing and verification before execution of all Sensors, Questions, Actions, Sensor Libraries, File Shards, etc. Enabling signing does away with the ability of an attacker to conduct Man in the Middle (MitM) attacks for the purposes of remote code execution and precludes the modification of the aforementioned data elements in transit. Additionally, Tanium supports object level signing for content ingested into the Tanium platform. This allows for the detection and rejection of changes to objects (sensors, actions, etc.) by even a privileged user within Tanium.Tanium has built-in signing capabilities enabled by default when installed. Cryptographic signing and verification of all Sensors, Questions, Actions, Sensor Libraries, File Shards, etc. before execution will be enforced by Tanium. Signing will prevent MitM remote code execution attacks and will protect data element in transit. Tanium also supports object level signing for content within the Tanium platform.

Check content

Using a web browser on a system that has connectivity to the Tanium Server, access the Tanium Server web user interface (UI) and log on with CAC. Click on "Administration". Select the "Global Settings" tab. In the search box beside "Show Settings Containing:" type "AllQuestionsRequireSignatureFlag". Enter. If no results are returned, this is a finding since this setting needs to be explicitly set. If results are returned for “AllQuestionsRequireSignatureFlag” but the value is not "1", this is a finding.

Fix text

Using a web browser on a system that has connectivity to the Tanium Server, access the Tanium Server web user interface (UI) and log on with CAC. Click on "Administration". Select the "Global Settings" tab. Click on "+ Add New Setting". In "Create New Setting" dialog box enter "sign_all_questions_flag" for "Setting Name:". Enter "1" for "Setting Value:". Select "Numeric" from "Value Type" drop-down list. Select "Clients" from "Affects" drop-down list. Click “Save”. Click on "Administration". Select the "Global Settings" tab. Click on "+ Add New Setting". In "Create New Setting" dialog box, enter "AllQuestionsRequireSignatureFlag" for "Setting Name:". Enter "1" for "Setting Value:". Select "Numeric" from "Value Type" drop-down list. Select "Clients" from "Affects" drop-down list. Click “Save”.

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.