From Application Security and Development Security Technical Implementation Guide
Part of SRG-APP-000506
Associated with: CCI-000172
When an application provides users with the ability to concurrently logon, an event must be recorded that indicates the user has logged on from different workstations. It is important to ensure that audit logs differentiate between the two sessions.
Review the application documentation and interview the application administrator to identify where log records are stored. Access log records then log on to the application as a regular user from one workstation. Take note of workstation IP address and confirm the address as the source workstation. Have the application administrator log on to the application from another workstation using the same account. Validate the IP address of the second workstation is recorded in the logs. If the application does not create an audit record when concurrent logons occur from different workstations, this is a finding.
Configure the application to log concurrent logons from different workstations.