The Arista Multilayer Switch must use FIPS-compliant mechanisms for authentication to a cryptographic module.

From Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Part of SRG-APP-000179-NDM-000265

Associated with: CCI-000803

SV-81687r1_rule The Arista Multilayer Switch must use FIPS-compliant mechanisms for authentication to a cryptographic module.

Vulnerability discussion

Unapproved mechanisms that are used for authentication to the cryptographic module are not verified and therefore cannot be relied upon to provide confidentiality or integrity, and DoD data may be compromised.Network devices utilizing encryption are required to use FIPS-compliant mechanisms for authenticating to cryptographic modules.FIPS 140-2 is the current standard for validating that mechanisms used to access cryptographic modules utilize authentication that meets DoD requirements.

Check content

Review the device configuration via the “show running-config” command for the following statement: management ssh fips restrictions If this statement is not present, this is a finding.

Fix text

Enable FIPS restrictions via the following commands: Enable Configure Management ssh Fips restrictions Exit Additionally, the switch should be configured to use its Hardware Random Number Generator as a source of entropy for the SSH protocol. To enable this, configure: Enable Configure Management security Entropy source hardware Once this has been changed, regenerate the SSH RSA Keys with: Reset ssh hostkey rsa

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.

You can obtain data about documents and items in other formats. Simply provide an HTTP header Accept: text/turtle or Accept: application/rdf+xml.

Powered by sagemincer