The Arista Multilayer Switch must generate audit records when concurrent logons from different workstations occur.

From Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide

Part of SRG-APP-000506-NDM-000323

Associated with: CCI-000172

SV-75335r1_rule The Arista Multilayer Switch must generate audit records when concurrent logons from different workstations occur.

Vulnerability discussion

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one. Audit records can be generated from various components within the information system (e.g., module or policy filter).

Check content

Determine if the network device generates audit records when concurrent logons from different workstations occur. If the network device does not generate audit records when concurrent logons from different workstations occur, this is a finding. Verify by reviewing log files to show concurrent logons to the system via the "Show Logging" command.

Fix text

Configure the network device to generate audit records when concurrent logons from different workstations occur. Enable logging level 6 to ensure this event is captured. Switch(config)#logging trap 6 switch(config)#logging level all 6