From Arista MLS DCS-7000 Series NDM Security Technical Implementation Guide
Part of SRG-APP-000374-NDM-000299
Associated with: CCI-001890
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Determine if the network device records time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT). This requirement may be verified by demonstration or configuration review. If the network device does not record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT), this is a finding. This can be configured with the following command: clock timezone GMT and verified by show run section clock Log records can be validated with: show logging
Configure the network device to record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT). This can be configured with the following command: clock timezone GMT