The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions.
Determine if the network device is configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources. If the network device is not configured to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources, this is a finding. Verify with: switch#show NTP status Identify the NTP status and available time sources.
Configure the network device to synchronize internal information system clocks with the primary and secondary time sources located in different geographic regions using redundant authoritative time sources. Configuration Example: switch(config)#ntp server HOST switch(config)#ntp server HOST prefer