The network device must synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.

From Network Device Management Security Requirements Guide

Part of SRG-APP-000372-NDM-000297

Associated with: CCI-002046

SV-69329r1_rule The network device must synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.

Vulnerability discussion

Inaccurate time stamps make it more difficult to correlate events and can lead to an inaccurate analysis. Determining the correct time a particular event occurred on a system is critical when conducting forensic analysis and investigating system events. Synchronizing internal information system clocks provides uniformity of time stamps for information systems with multiple system clocks and systems connected over a network. Organizations should consider setting time periods for different types of systems (e.g., financial, legal, or mission-critical systems). Organizations should also consider endpoints that may not have regular access to the authoritative time server (e.g., mobile, teleworking, and tactical endpoints). This requirement is related to the comparison done every 24 hours in CCI-001891 because a comparison must be done in order to determine the time difference.The organization-defined time period will depend on multiple factors, most notably the granularity of time stamps in audit logs. For example, if time stamps only show to the nearest second, there is no need to have accuracy of a tenth of a second in clocks.

Check content

Check the network device configuration to determine if the device synchronizes internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period. If this synchronization is not occurring when the time difference is greater than the organization-defined time period, this is a finding.

Fix text

Configure the network device to synchronize internal information system clocks to the authoritative time source when the time difference is greater than the organization-defined time period.