From SOLARIS 10 SPARC SECURITY TECHNICAL IMPLEMENTATION GUIDE
Part of GEN000000-SOL00300
Associated with IA controls: ECCD-2, ECCD-1
Associated with: CCI-000366
If the EEPROM security-mode parameter is not set to full or command, then unauthorized access to system EEPROM can take place. In normal situations, when the system is in a controlled access area and it is desirable to have it automatically reboot upon loss of and restoring of power, for instance, then command mode with the autoboot parameter set to true is recommended.
If the system does not have an OBP / EEPROM, this is not applicable. # eeprom | grep security-mode If the EEPROM security-mode parameter is not set to full or command, this is a finding.
Set the system EEPROM security-mode parameter to full or command. # eeprom security-mode=full OR # eeprom security-mode=command The system will prompt the user for a password. This should be securely stored.