From HP FlexFabric Switch NDM Security Technical Implementation Guide
Part of SRG-APP-000375-NDM-000300
Associated with: CCI-001889
Without sufficient granularity of time stamps, it is not possible to adequately determine the chronological order of records. Time stamps generated by the application include date and time. Granularity of time measurements refers to the degree of synchronization between information system clocks and reference clocks.
Check if info-center is configured to provide timestamp:
[HP] display info-center
Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date
Check logfile content to determine if the time stamp is present:
Configure timestamp on the logs on the HP FlexFabric Switch: [HP] info-center timestamp date By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY which provides required granularity.
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer