The HP FlexFabric Switch must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

From HP FlexFabric Switch NDM Security Technical Implementation Guide

Part of SRG-APP-000374-NDM-000299

Associated with: CCI-001890

SV-80743r1_rule The HP FlexFabric Switch must record time stamps for audit records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Vulnerability discussion

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Check content

Determine if time zone is configured on the HP FlexFabric Switch: [HP] display clock 15:00:32 EST Thu 07/09/2015 Time Zone : EST minus 05:00:00 Check if info-center is configured to provide timestamp: [HP] display info-center Information Center: Enabled Console: Enabled Monitor: Enabled Log host: Enabled 192.100.50.27, port number: 514, host facility: local7 Log buffer: Enabled Max buffer size 1024, current buffer size 512 Current messages 66, dropped messages 0, overwritten messages 0 Log file: Enabled Security log file: Enabled Information timestamp format: Log host: Date Other output destination: Date Check logfile content to determine if the time stamp is present: cd logfile/ more logfile.log %@9377%Jan 20 23:31:03:567 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is dis info-center %@9378%Jan 20 23:31:09:342 2011 HP5930_SUT SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=16.123.122.155-User=admin; Command is qui If the HP FlexFabric Switch is not configured to enable timestamp in the log and if time zone is not configurable, this is a finding.

Fix text

Configure time zone on the HP FlexFabric Switch: [HP] clock timezone EST minus 5:00:00 Configure timestamp on the logs on the HP FlexFabric Switch: [HP] info-center timestamp date Note: By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY.

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.

You can obtain data about documents and items in other formats. Simply provide an HTTP header Accept: text/turtle or Accept: application/rdf+xml.

Powered by sagemincer