From HP FlexFabric Switch NDM Security Technical Implementation Guide
Part of SRG-APP-000374-NDM-000299
Associated with: CCI-001890
If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.
Determine if time zone is configured on the HP FlexFabric Switch:
[HP] display clock
15:00:32 EST Thu 07/09/2015
Time Zone : EST minus 05:00:00
Check if info-center is configured to provide timestamp:
[HP] display info-center
Information Center: Enabled
Console: Enabled
Monitor: Enabled
Log host: Enabled
192.100.50.27,
port number: 514, host facility: local7
Log buffer: Enabled
Max buffer size 1024, current buffer size 512
Current messages 66, dropped messages 0, overwritten messages 0
Log file: Enabled
Security log file: Enabled
Information timestamp format:
Log host: Date
Other output destination: Date
Check logfile content to determine if the time stamp is present:
Configure time zone on the HP FlexFabric Switch: [HP] clock timezone EST minus 5:00:00 Configure timestamp on the logs on the HP FlexFabric Switch: [HP] info-center timestamp date Note: By default, the device uses internal system clocks to generate time stamps for audit records in the date format - MMM DD hh:mm:ss:xxx YYYY.
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer