Information Security (INFOSEC) - Secure Room Storage Standards - Balanced Magnetic Switch (BMS) on Perimeter Doors

From Traditional Security

Part of Information Security (INFOSEC) - Secure Room Standards - BMS on Perimeter Doors

Associated with IA controls: PESS-1, PEPF-2

SV-41542r2_rule Information Security (INFOSEC) - Secure Room Storage Standards - Balanced Magnetic Switch (BMS) on Perimeter Doors

Vulnerability discussion

Failure to meet standards for ensuring that there is structural integrity of the physical perimeter surrounding a secure room (AKA: collateral classified open storage area) IAW DoD Manual 5200.01, Volume 3 could result in the undetected loss or compromise of classified material. When a physical Intrusion Detection System (IDS) is used as the supplemental protection measure (in lieu of 4-hour random checks) for secure rooms there is a requirement to place a Balanced Magnetic Switch (BMS) alarm contact on the primary ingress/egress door and any secondary/emergency exit doors. This alarm sensor is an essential part of any properly installed IDS and ensures that doors opened by force or that are left open are immediately detected. A BMS (AKA: triple biased alarm contact) is the most difficult door alarm contact to defeat and must be used in lieu of dual biased or simple alarm contacts.

Check content

Where an IDS is used in lieu of 4-hour random checks, for secure rooms or collateral classified open storage areas containing SIPRNet assets, each perimeter door (primary and secondary) shall be protected by a balanced magnetic switch (BMS) that meets the standards of UL 634. NOTE: Ensure the alarm contact is an actual BMS, which is defined as a "Triple Biased" alarm contact. Introduction of a foreign magnet by an intruder in an attempt to defeat the BMS will result in an alarm being sent. If used, Simple and Dual Biased contacts are not BMS and will result in a CAT II finding. No alarm contacts on all doors is a CAT I finding. TACTICAL ENVIRONMENT: This check is applicable where Secure Rooms are used to protect classified materials or systems in a tactical environment. The only exception will be for urgent (short term) tactical operations or other contingency situations where fixed facilities and equipment are not yet present or incapable of being used.

Fix text

Where an IDS is used in lieu of 4-hour random checks, for secure rooms or collateral classified open storage areas containing SIPRNet assets, each perimeter door (primary and secondary) must be protected by a balanced magnetic switch (BMS) that meets the standards of UL 634. NOTE: The alarm contact must be an actual BMS, which is defined as a "Triple Biased" alarm contact. Introduction of a foreign magnet by an intruder in an attempt to defeat the BMS will result in an alarm being sent. Simple and Dual Biased contacts are not BMS and will result in a finding.

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.

You can obtain data about documents and items in other formats. Simply provide an HTTP header Accept: text/turtle or Accept: application/rdf+xml.

Powered by sagemincer