Information Security (INFOSEC) - Vault/Secure Room Storage Standards - Door Combination Lock Meeting Federal Specification FF-L-2740

From Traditional Security

Part of Information Security (INFOSEC) - Vault/Secure Room Standards - Combination Lock

Associated with IA controls: PESS-1

SV-41529r2_rule Information Security (INFOSEC) - Vault/Secure Room Storage Standards - Door Combination Lock Meeting Federal Specification FF-L-2740

Vulnerability discussion

Failure to meet Physical Security storage standards could result in the undetected loss or compromise of classified material.

Check content

*This check is specifically for vaults and secure rooms or open storage areas containing inspectable SIPRNet assets*: Check the primary ingress/egress door to ensure a proper combination lock is installed and is being used. Door must be equipped with a built-in GSA-approved combination lock meeting Federal Specification FF-L-2740, such as the X07, X09 locks. NOTE: The use of automated access control systems (ACS) is encouraged to control access to secure room space during working hours; however, electrically actuated locks (e.g., cypher and magnetic access card locks) do not afford by themselves the required degree of protection for classified information and must not be used as a substitute for the combination locks meeting Federal Specification FF-L-2740. TACTICAL ENVIRONMENT: This check is applicable where vaults or secure rooms are used to protect classified materials or systems. The only exception will be for urgent (short term) tactical operations or other contingency situations where fixed facilities and equipment are not yet present or incapable of being used.

Fix text

*This requirement is specifically for vaults and secure rooms or open storage areas containing inspectable SIPRNet assets*: The primary ingress/egress door must be equipped with a proper combination lock that is installed properly and is being used. Door must be equipped with a built-in GSA-approved combination lock meeting Federal Specification FF-L-2740, such as the X07, X09 locks. NOTE: The use of automated access control systems (ACS) is encouraged to control access to secure room space during working hours; however, electrically actuated locks (e.g., cypher and magnetic access card locks) do not afford by themselves the required degree of protection for classified information and must not be used as a substitute for the combination locks meeting Federal Specification FF-L-2740.

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.

You can obtain data about documents and items in other formats. Simply provide an HTTP header Accept: text/turtle or Accept: application/rdf+xml.

Powered by sagemincer