From Traditional Security
Part of PDS Monitoring - Technical Inspections
Associated with IA controls: DCSR-3, PESS-1, ECCT-2
A PDS that is not inspected, monitored and maintained as required could result in undetected access, sabotage or tampering of the unencrypted transmission lines. This could directly lead to the loss or compromise of classified.
Check to ensure: 1. Technical inspections of PDS are conducted at least one or more times annually IAW Table B-3, of the NSTISSI 7003. 2. Checks and results must be documented and retained on file for a minimum of 1-year - or longer if required by the DAA. 3. The person selected to accomplish the technical system inspection is trained to recognize changes in the technical aspects of PDS, e.g., by-pass circuitry, attachment or removal of devices or components, inappropriate or suspicious signal levels, and mechanical, TEMPEST. and RED/BLACK integrity of the PDS. If conducted by the CTTA this meets the requirement; otherwise, sufficient documented proof of training must be provided for the person conducting the inspection. Note: This check is applicable within a tactical environment in a fixed facility but not applicable in a mobile field environment.
Correction of this finding can only be made by complete compliance with all the following NSTISSI 7003 requirements: 1. Technical inspections of PDS must be conducted at least one or more times annually IAW Table B-3, of the NSTISSI 7003. 2. Checks and results must be documented and retained on file for a minimum of 1-year, or longer if required by the DAA. 3. The person selected to accomplish the technical system inspection must be trained to recognize changes in the technical aspects of PDS, e.g., by-pass circuitry, attachment or removal of devices or components, inappropriate or suspicious signal levels, and mechanical, TEMPEST. and RED/BLACK integrity of the PDS. If conducted by the CTTA this meets the requirement; otherwise, sufficient documented proof of training must be provided for the person conducting the inspection. Note: This check is applicable within a tactical environment in a fixed facility but not applicable in a mobile field environment.
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer