The audit system must alert the SA when the audit storage volume approaches its capacity.

From Solaris 11 X86 Security Technical Implementation Guide

Part of SRG-OS-000048

Associated with: CCI-000143

SV-60709r1_rule The audit system must alert the SA when the audit storage volume approaches its capacity.

Vulnerability discussion

Filling the audit storage area can result in a denial of service or system outage and can lead to events going undetected.

Check content

Fix text

The root role is required. This action applies to the global zone only. Determine the zone that you are currently securing. # zonename If the command output is "global", this action applies. Add an audit_warn alias to /etc/mail/aliases that will forward to designated system administrator(s). # pfedit /etc/mail/aliases Insert a line in the form: audit_warn:user1,user2 Put the updated aliases file into service. # newaliases