From LG Android 5.x Interim Security Configuration Guide
Part of PP-MDF-991000
Associated with: CCI-000366
Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events.
This validation procedure is performed on both the MDM Administration Console and the LG Android device. Check whether the appropriate setting is configured on the MDM Administration Console: 1. Ask the MDM administrator to display the "Allow System Time Changes" check box. 2. Verify the setting is disabled. On the LG Android device: 1. Open the device settings. 2. Select "Date and time". 3. Verify the "Auto date and time" check box is checked. 4. Verify a user cannot deselect the "Auto date and time" check box. If either the "Allow System Time Changes" is not disabled in the MDM administration console; or the "Auto date and time" check box is not selected on the device; or if it is possible to deselect this option on the device, this is a finding.
On the MDM Console, disable "Allow System Time Changes".