From MobileIron Core v9.x MDM Security Technical Implementation Guide
Part of PP-MDM-991000
Associated with: CCI-000057
A session time-out lock is a temporary action taken when a user stops work and moves away from the immediate physical vicinity of the information system but does not log out because of the temporary nature of the absence. Rather than relying on the user to manually lock their application session prior to vacating the vicinity, applications need to be able to identify when a user's application session has idled and take action to initiate the session lock.
Login to each of the MobileIron Core Server portals (system manager portal and server administrator portal) and wait for 15 minutes without performing any operation. If the session lock does not occur after 15 minutes of inactivity on each MobileIron Core Server portal, this is a finding.
Configure the MobileIron Core Server to initiate a session lock after a 15-minute period of inactivity. 1. Login to the MobileIron Core Server administrator portal as a user with the security configuration administrator role using a web browser. 2. Select "Settings" on the web page. 3. Select "General" on the web page. 4. Select "Timeout "on the web page. 5. Set the "Idle Session Timeout" value to "15" on the web page. 6. Select "Save" on the web page.
Lavender hyperlinks in small type off to the right (of CSS
class id
, if you view the page source) point to
globally unique URIs for each document and item. Copy the
link location and paste anywhere you need to talk
unambiguously about these things.
You can obtain data about documents and items in other
formats. Simply provide an HTTP header Accept:
text/turtle
or
Accept: application/rdf+xml
.
Powered by sagemincer