The vRA PostgreSQL database must be configured to use a syslog facility.

From VMW vRealize Automation 7.x PostgreSQL Security Technical Implementation Guide

Part of SRG-APP-000360-DB-000320

Associated with: CCI-001858

SV-100039r1_rule The vRA PostgreSQL database must be configured to use a syslog facility.

Vulnerability discussion

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability, and system operation may be adversely affected. The appropriate support staff include, at a minimum, the ISSO and the DBA/SA.Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).

Check content

At the command prompt, execute the following command: # grep '^\s*logging_collector\b' /storage/db/pgdata/postgresql.conf If "logging_collector" is not "on", this is a finding.

Fix text

At the command prompt, execute the following commands: # /opt/vmware/vpostgres/current/bin/psql -U postgres -c "ALTER SYSTEM SET logging_collector TO 'on';" # /opt/vmware/vpostgres/current/bin/psql -U postgres -c "SELECT pg_reload_conf();"