The system must use time sources local to the enclave.

From SOLARIS 10 SPARC SECURITY TECHNICAL IMPLEMENTATION GUIDE

Part of GEN000244

Associated with: CCI-000160

SV-26305r2_rule The system must use time sources local to the enclave.

Vulnerability discussion

A synchronized system clock is critical for the enforcement of time-based policies and the correlation of logs and audit records with other systems. The network architecture should provide multiple time servers within an enclave that provide local service to the enclave and synchronize with time sources outside of the enclave.If this server is an enclave time server, this requirement is not applicable.If the system is completely isolated (no connections to networks or other systems), time synchronization is not required as no correlation of events or operation of time-dependent protocols between systems will be necessary. If the system is completely isolated, this requirement is not applicable.

Check content

Determine the zone that you are currently securing. # zonename If the command output is not "global", this is not applicable. Check the NTP daemon configuration. # grep '^server' /etc/inet/ntp.conf If an NTP server is listed outside of the enclave, this is a finding.

Fix text

Remove the server line from /etc/inet/ntp.conf for each NTP server that is external to the enclave.

Pro Tips

Lavender hyperlinks in small type off to the right (of CSS class id, if you view the page source) point to globally unique URIs for each document and item. Copy the link location and paste anywhere you need to talk unambiguously about these things.

You can obtain data about documents and items in other formats. Simply provide an HTTP header Accept: text/turtle or Accept: application/rdf+xml.

Powered by sagemincer