From z/OS ACF2 STIG
Part of ACF0670
Associated with IA controls: DCCS-1, DCCS-2
Associated with: CCI-002145 CCI-002883 CCI-003014
LOGONIDs could be intentionally created that correspond to the GSO MAINT records. Then the maintenance programs could be used to gain unauthorized access to the system. This could result in the compromise of the confidentiality, integrity, and availability of the operating system, ACP, and customer data.
a) Refer to the following reports produced by the ACF2 Data Collection: - ACF2CMDS.RPT(ACFGSO) - ACF2CMDS.RPT(ATTMAINT) Automated Analysis Refer to the following report produced by the ACF2 Data Collection Checklist: - PDI(ACF0670) b) If every GSO MAINT record has a corresponding maintenance logonid, there is NO FINDING. c) If any GSO MAINT record does not have a corresponding maintenance logonid, this is a FINDING.
The IAO will ensure that an associated user logonid exists for each special GSO maintenance record identifying the program(s) that it is permitted to access and the library where the program(s) resides. An associated GSO MAINT record will exist for each special user logonid, identifying the program(s) that it is permitted to access and the library where the program(s) resides. Example: SET LID CHANGE DFSMSHSM MAINT